type='html'>This circuit can be used for monitoring the voltage level of an automobile battery. When battery voltage is 11.5V or less transistor Q1 will be On and LED D1 will be glowing.When battery voltage is between 11.5 - 13.5V, the transistor Q2 will be On and the LED D2 will be glowing.When battery voltage is above 13.5V the transistor Q3 will be On and the LED D3 will be glowing.
The battery 12 volt to be monitored can be connected between the terminals A and B and for convenience use LEDs of different colour .
List component of Monitor status battery 12 volt
-R1,R3,R6: 1k 1/4W Resistance
-R2: 100K 1/4W Resistance
-R4,R5,R7,R8: 3.3K 1/4W Resistance
-D1: LED red color
-D2: LED yellow color
-d7: LED green COLOR
-D2,D4,D5,D8,D9: 1N4148 diode 1 ampere
-D6: BZX79C10 diode Zener 10 volt
-D10: BZX79C12 diode Zener 12 volt
-Q1,Q2: BC547 NPN transistor
-Q3: BC557 PNP transistor
Spesifikasi BC547
This device is designed for use as general purpose amplifiers and switches requiring collector currents to 300 mA. Sourced from Process 10. See PN100A for characteristics.
-(VCEO) Collector-Emitter: Voltage 45 V
-(VCES) Collector-Base Voltage: 50 V
-(VEBO) Emitter-Base Voltage: 6.0 V
-(IC) Collector Current: Continuous 500 mA
-(TJ) Tstg Operating and Storage Junction Temperature Range: -55 to +150 °C
Rangkaian Lampu LED,Motor,12VDC to 220VAC,Inverter Circuit,Rangkaian LED 220VAC,600 Watt Darlington,Power Amplifier Circuit
Showing posts with label Monitor. Show all posts
Showing posts with label Monitor. Show all posts
Tuesday, August 7, 2012
Saturday, June 30, 2012
Rangkaian Charge Monitor for 12V battery
type='html'>This circuit project is a function for monitoring the charge level of 12 volt batteries continuously. The circuit possesses two vital features:
How to Work a Circuit of Charge Monitor for 12V Battery
- reduces the requirement of human attention by about 85%.
- highly accurate and sophisticated methods.
A battery is a vital element of any battery-backed system. In many cases the battery is more expensive than the systems it is backing up. We need to Adopt Hence all practical measures to Conserve battery life.
As per manufacturer's data sheets, a 12V rechargeable battery operated Should be within 10. IV and 13.8V. When the battery charges higher than 13.8V it is said to be overcharged, and it discharges below 10.IV Pls Can it be Deeply discharged. A single event of overcharge or deep discharge Can bring down the charge-holding capacity of a battery by 15 to 20%.
Note:
For calibrating the upper and lower reference levels, a digital multimeter and a variable regulated power supply source are required. For calibrating the lower reference voltage, follow the steps given below:
As per manufacturer's data sheets, a 12V rechargeable battery operated Should be within 10. IV and 13.8V. When the battery charges higher than 13.8V it is said to be overcharged, and it discharges below 10.IV Pls Can it be Deeply discharged. A single event of overcharge or deep discharge Can bring down the charge-holding capacity of a battery by 15 to 20%.
Note:
For calibrating the upper and lower reference levels, a digital multimeter and a variable regulated power supply source are required. For calibrating the lower reference voltage, follow the steps given below:
- Set the output of power supply source to 10. IV.
- Connect the power supply source in place of the battery.
- Now the display will show some reading. At this point vary preset VR2 until the reading on the display just changes from 1 to 0.
- The higher reference voltage is calibrated similarly by setting the power supply to 13.8V and varying preset VR1 until reading on the display just changes from 8 to 9.
How to Work a Circuit of Charge Monitor for 12V Battery
Input from the battery under test is applied to LM3914 1C. This applied voltage is ranked anywhere between 0 and 10, depending upon its magnitude. The lower reference voltage of 10.IV is ranked '0' and the upper voltage of 13.8V is ranked as '10.' (Outputs 9 and 10 are logically ORed in this circuit.) This calibration of reference voltages is explained above.
1C 74LS147 is a decimal-to-BCD priority encoder which converts the output of LM3914 into its BCD complement. The true BCD is obtained by using the hex inverter 74LS04. This BCD output is displayed as a decimal digit after con version using IC5 (74LS247), which is a BCD-to-seven-segment decoder/driver. The seven-segment LED display (LTS-542) is used because it is easy to read compared to a bar graph or, for that matter, an analogue meter. The charge status of the battery can be quickly calculated from the display. For instance, if the display shows 4, it means that the battery is charged to 40 per cent of its maximum value of 13.8V.
The use of digital principles enables us to employ a buzzer that sounds whenever there is an overcharge or deep discharge, or there is a need to conserve battery charge. A buzzer is wired in the circuit such that it sounds whenever battery-charge falls to ten per cent. At this point it is recommended that unnecessary load be switched off and the remaining charge be conserved for more important purposes.
Another simple combinational logic circuit can also be designed that will sound the buzzer when the display shows 9. Further charging should be stopped at this point in order to pre vent overcharge.
1C 74LS147 is a decimal-to-BCD priority encoder which converts the output of LM3914 into its BCD complement. The true BCD is obtained by using the hex inverter 74LS04. This BCD output is displayed as a decimal digit after con version using IC5 (74LS247), which is a BCD-to-seven-segment decoder/driver. The seven-segment LED display (LTS-542) is used because it is easy to read compared to a bar graph or, for that matter, an analogue meter. The charge status of the battery can be quickly calculated from the display. For instance, if the display shows 4, it means that the battery is charged to 40 per cent of its maximum value of 13.8V.
The use of digital principles enables us to employ a buzzer that sounds whenever there is an overcharge or deep discharge, or there is a need to conserve battery charge. A buzzer is wired in the circuit such that it sounds whenever battery-charge falls to ten per cent. At this point it is recommended that unnecessary load be switched off and the remaining charge be conserved for more important purposes.
Another simple combinational logic circuit can also be designed that will sound the buzzer when the display shows 9. Further charging should be stopped at this point in order to pre vent overcharge.
Subscribe to: