Rangkaian Pendeteksi|Sensor Ketinggian Level Air

type='html'>
This is the circuit diagram of a simple Water level detection (Pendeteksi|Sensor Ketinggian Level Air) for home and industries. In fact the the level of any conductive non corrosive liquids can be measured using this circuit. Pendeteksi|Sensor Ketinggian Level Air is based on 5 transistor switches.Each transistor is switched on to drive the corresponding LED , when its base is supplied with current through the water through the electrode probes.

One electrode probe is (F) with 6V AC is placed at the bottom of tank. Next probes are placed step by step above the bottom probe. When water is rising the the base of each transistor gets electrical connection to 6V AC through water and the corresponding probe. Which in turn makes the transistors conduct to glow LED and indicate the level of water. The ends of probes are connected to corresponding points in the circuit as shown in circuit diagram. Insulated Aluminum wires with end insulation removed will do for the probe. Arrange the probes in order on a PVC pipe according to the depth and immerse it in the tank. AC voltage is use to prevent electrolysis at the probes. So this setup will last really long. I guarantee at least a 2 years of maintenance free operation.That’s what I got and is still going.


Circuit of Water Level
Skema Rangkaian Sensor Ketinggian Level Air


list Components of Water level Detection
  • T1 - T5 BC 548 or 2N2222
  • R1-R5 2.2K 1/4 W
  • R6-R10 22K 1/4 W
  • D1 - D5 LED’s

Use a transformer 6V 500 mA for power supply. Do not use a rectifier! we need pure AC. Use good quality insulated Aluminum wire for probes. If Aluminum wires are not available try Steel or Tin. Copper is the worst. Try the circuit first on a bread board and if not working properly, make adjustments with the resistance values . This is often needed because conductivity of water changes slightly from place to place.

Saturday, June 30, 2012

Rangkaian Radar Pompa Air (Kontrol Ketinggian Air)

type='html'>Radar Pompa Air (Kontrol Ketinggian Air)

By means of a Relay, employed to drive a water pump, this circuit provides automatic level control of a water reservoir or well.
Skema Rangkaian Radar Pompa air


Note:
  • The two steel rods must be supported by a small insulated (wooden or plastic) board.
  • The circuit can be used also with non-metal tanks, provided a third steel rod having about the same height of the tank will be added and connected to the circuit's negative ground.
The shorter steel rod is the "water high" sensor, whereas the longer is the "water low" sensor. When the water level is below both sensors, IC1C output (pin #10) is low; if the water becomes in contact with the longer sensor the output remains low until the shorter sensor is reached. At this point IC1C output goes high, Q1 conducts, the Relay is energized and the pump starts operating.

Now, the water level begins to decrease and the shorter sensor will be no longer in contact with the water, but IC1C output will be hold high by the signal return to pin #5 of IC1B, so the pump will continue its operation. But when the water level falls below the longer sensor, IC1C output goes low and the pump will stop.

SW1 is optional and was added to provide reverse operation. Switching SW1 in order to connect R3 to pin #11 of IC1D, the pump will operate when the reservoir is nearly empty and will stop when the reservoir is full. In this case, the pump will be used to fill the reservoir and not to empty it as in the default operating mode.

List Component
  • R1,R2: 15K 1/4W Resistors
  • R3: 10K 1/4W Resistor
  • R4: 1K 1/4W Resistor
  • D1: LED
  • D2: 1N4148 Diode
  • IC1: 4001
  • Q1: BC337 NPN Transistor
  • SW1: witch
  • RL1: Relay with SPDT 2A @ 230V switch, Coil Voltage 12V